18
1 – Screw M4 x 5
2 – Draught regulator plug
with chain
3 – Front left and right part of
shell incl. insulation
4 – Stoking door
5 – Door tap
6 – Nut M8
7 – Washer Ø 8
8 – Stoking door hinge
9 – Nut M8
10 – Washer Ø 8
11 – Cleaning cover
12 – Combustion space
barrier
Fig. no. 14 Cleaning cover dismounting
3.3 IMPORTANT NOTICE
1. The boiler can be operated only by adult persons acquainted with this operation manual. It is inadmissible to
leave the children unattended by adults near the boiler. The boiler construction invervention, which can
endanger the attendant´s safety, eventually the housemate´s safety, is inadmissible.
2. If there occurs a danger or flammable vapours and gases development and penetration into the boiler room,
or at works accompanied by the temporary development of the fire or explosion (gluing the floor covering,
painting with combustible painting colours), the boiler must be duly closed down before the works start.
3. It is FORBIDDEN to use the flammable liquids for VIADRUS HERCULES U 24 boiler firing.
4. It is FORBIDDEN to overheat the boiler during its operation. Fill the boiler under the lower edge of stoking
door. Open the stoking door by use of plastic handle and half-open the ash door to smoke vent the smoke
gases.
5. It is forbidden to put the flammable materials on the boiler or in its near distance.
6. When cleaning the ashes at VIADRUS HERCULES U 24 boiler there must not be put any flammable
materials within minimally 1500 mm distance from the boiler.
7. When operating the boiler at the temperature lower than 60 C the boiler drum can be bedewed, which means
the low-temperature corrosion and reduction of boiler drum service life. Therefore we recommend to operate
the boiler at the temperature of 60 C and higher.
8. After the heating season termination it is necessary to clean the boiler, smoke-flues and smoke adapter
properly. Spread the graphitic grease on swivel taps, smoke flap mechanism and on other flexible parts of
boiler. Keep the boiler room clean and dry.
9. Possible corrosion marks on boiler drum don´t mean a defect and they don´t affect the boiler function.
The list of contractual service organizations is attached separately.